Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study

dc.authorid Yilmaz, Hakan/0000-0002-9564-6212
dc.authorid Cakmak, Gulce/0000-0003-1751-9207
dc.authorscopusid 57217863941
dc.authorscopusid 57210447211
dc.authorscopusid 57193734310
dc.authorscopusid 6505629724
dc.authorscopusid 35583824600
dc.authorwosid Cakmak, Gulce/GRE-6472-2022
dc.authorwosid ÇAKMAK, GONCA/C-6464-2018
dc.authorwosid YILMAZ, HAKAN/JVO-9077-2024
dc.authorwosid Yilmaz, Hakan/U-1749-2018
dc.contributor.author Cakmak, Gulce
dc.contributor.author Yilmaz, Hakan
dc.contributor.author Santos, Alejandro Trevino
dc.contributor.author Kokat, Ali Murat
dc.contributor.author Yilmaz, Burak
dc.date.accessioned 2024-05-25T11:26:35Z
dc.date.available 2024-05-25T11:26:35Z
dc.date.issued 2022
dc.department Okan University en_US
dc.department-temp [Cakmak, Gulce] Univ Bern, Buser Fdn Scholar Implant Dent, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland; [Yilmaz, Hakan] Yeditepe Univ, Fac Dent, Dept Orthodont, Istanbul, Turkey; [Santos, Alejandro Trevino] Univ Nacl Autonoma Mexico, Fac Dent, Postdoctoral & Res Div, Mexico City, DF, Mexico; [Kokat, Ali Murat] Istanbul Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Yilmaz, Burak] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland; [Yilmaz, Burak] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA en_US
dc.description Yilmaz, Hakan/0000-0002-9564-6212; Cakmak, Gulce/0000-0003-1751-9207 en_US
dc.description.abstract Purpose To compare the accuracy (trueness and precision) of scans of a newly introduced intraoral scanner (IOS) (Virtuo Vivo) and a widely used IOS (Trios 3) to a laboratory scanner (LBS) (Cares 7 SERIES) for 6 implants placed in an edentulous mandible, and to investigate the effect of scan body location on trueness. Material and methods Scanbodies were tightened on 6 implants placed in an edentulous polymethylmethacrylate mandibular model. An industrial scanner was utilized to generate a master reference model STL file. Three different scanners were used to scan the model (2 IOSs and 1 LBS), and the scans (n = 10) were exported into STL files. Best-fitting algorithm was used to superimpose test scans over the MRM-STL (nominal). ANOVA and Tukey HSD tests were performed to analyze the data (alpha = 0.05). Results The distance deviations in Car7-LBS scans were the highest (p < 0.001), whereas those in Tri-IOS scans were the lowest (p < 0.001). Vir-IOS had lower angular deviations than those of Tri-IOS (p = 0.031). In Vir-IOS scans, SB5 had higher distance deviations than SB2 (p = 0.029) and SB3 (p = 0.044). In Car7-LBS scans, SB1 had higher distance deviations than SB3 (p = 0.015) and SB5 (p = 0.005). In Tri-IOS scans, SB1 had higher mean distance deviations than SB2 and SB5 (p = 0.005). Vir-IOS had lower precision than Car7-LBS (distance deviation data) (p = 0.01). No difference was found among scanners for the precision of angular deviation data (p = 0.840). Conclusion When trueness and precision were considered, distance and angular deviations depended on the scanner type. None of the scanners outperformed others in accuracy considering all distance and angular deviations. Scan body location affected only the trueness (distance deviations). en_US
dc.description.sponsorship Universitat Bern en_US
dc.description.sponsorship Open access funding provided by Universitat Bern. en_US
dc.identifier.citationcount 9
dc.identifier.doi 10.1111/jopr.13418
dc.identifier.endpage 426 en_US
dc.identifier.issn 1059-941X
dc.identifier.issn 1532-849X
dc.identifier.issue 5 en_US
dc.identifier.pmid 34453466
dc.identifier.scopus 2-s2.0-85115254864
dc.identifier.scopusquality Q1
dc.identifier.startpage 419 en_US
dc.identifier.uri https://doi.org/10.1111/jopr.13418
dc.identifier.uri https://hdl.handle.net/20.500.14517/994
dc.identifier.volume 31 en_US
dc.identifier.wos WOS:000697530000001
dc.identifier.wosquality Q1
dc.language.iso en
dc.publisher Wiley en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 18
dc.subject Accuracy en_US
dc.subject trueness en_US
dc.subject precision en_US
dc.subject mandible en_US
dc.subject implant en_US
dc.subject intraoral scanner en_US
dc.title Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study en_US
dc.type Article en_US
dc.wos.citedbyCount 16

Files