Predictors for Early Mortality in Patients With Implantable Cardiac Defibrillator for Heart Failure With Reduced Ejection Fraction

dc.authorid Ozcan, Kazim Serhan/0000-0002-5321-442X
dc.authorid Yumurtas, Ahmet Cagdas/0000-0002-7311-2826
dc.authorid Cinar, Tufan/0000-0001-8188-5020
dc.authorid Tezen, Ozan/0000-0002-2774-8348
dc.authorid Hayiroglu, Mert/0000-0001-6515-7349
dc.authorwosid Çinier, Göksel/Y-1715-2019
dc.authorwosid Cetin, Tugba/Mfj-7247-2025
dc.authorwosid Turkkan, Ceyhan/Hgv-1017-2022
dc.authorwosid Ozbilgin, Nazmiye/Mip-3381-2025
dc.authorwosid Ozcan, Kazim/O-3365-2018
dc.authorwosid Yumurtaş, Ahmet/Jac-4458-2023
dc.authorwosid Pay, Levent/Adr-2591-2022
dc.contributor.author Cinier, Goksel
dc.contributor.author Hayiroglu, Mert Ilker
dc.contributor.author Cinar, Tufan
dc.contributor.author Pay, Levent
dc.contributor.author Yumurtas, Ahmet Cagdas
dc.contributor.author Tezen, Ozan
dc.contributor.author Gurkan, Kadir
dc.date.accessioned 2024-05-25T12:18:13Z
dc.date.available 2024-05-25T12:18:13Z
dc.date.issued 2022
dc.department Okan University en_US
dc.department-temp [Cinier, Goksel; Hayiroglu, Mert Ilker; Pay, Levent; Yumurtas, Ahmet Cagdas; Tezen, Ozan; Eren, Semih; Kolak, Zeynep; Cetin, Tugba; Ozcan, Serhan; Ozbilgin, Nazmiye; Tekkesin, Ahmet Ilker; Alper, Ahmet Taha; Gurkan, Kadir] Dr Siyami Ersek Thorac & Cardiovasc Surg Training, Dept Cardiol, Istanbul, Turkey; [Cinar, Tufan] Sultan II Abdulhamid Han Training & Res Hosp, Dept Cardiol, Istanbul, Turkey; [Turkkan, Ceyhan] Okan Univ Hosp, Dept Cardiol, Istanbul, Turkey en_US
dc.description Ozcan, Kazim Serhan/0000-0002-5321-442X; Yumurtas, Ahmet Cagdas/0000-0002-7311-2826; Cinar, Tufan/0000-0001-8188-5020; Tezen, Ozan/0000-0002-2774-8348; Hayiroglu, Mert/0000-0001-6515-7349 en_US
dc.description.abstract Implantable cardioverter defibrillators (ICD) are recommended in heart failure with reduced ejection fraction (HFrEF) patients to reduce arrhythmic deaths. This study aimed to identify risk factors associated with mortality within one-year following the ICD. The data from our hospital's electronic database system was extracted for patients who were implanted ICD secondary to HFrEF between 2009 and 2019. Overall, 1107 patients were included in the present analysis. Mortality rate at one-year following the device implantation was 4.7%. In multivariate analysis; age, atrial fibrillation, New York Heart Association classification >2, blood urea nitrogen, pro-brain natriuretic peptide and albumin independently predicted one year mortality.(c) 2022 Cardiological Society of India. Published by Elsevier, a division of RELX India, Pvt. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.citationcount 1
dc.identifier.doi 10.1016/j.ihj.2022.01.003
dc.identifier.endpage 130 en_US
dc.identifier.issn 0019-4832
dc.identifier.issn 2213-3763
dc.identifier.issue 2 en_US
dc.identifier.pmid 35104458
dc.identifier.scopus 2-s2.0-85124194557
dc.identifier.scopusquality Q3
dc.identifier.startpage 127 en_US
dc.identifier.uri https://doi.org/10.1016/j.ihj.2022.01.003
dc.identifier.volume 74 en_US
dc.identifier.wos WOS:000805115400008
dc.identifier.wosquality N/A
dc.language.iso en
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 2
dc.subject Heart Failure With Reduced Ejection Fraction en_US
dc.subject Early Mortality en_US
dc.subject Implantable Cardiac Defibrillator en_US
dc.title Predictors for Early Mortality in Patients With Implantable Cardiac Defibrillator for Heart Failure With Reduced Ejection Fraction en_US
dc.type Article en_US

Files