The Influence of Interimplant Distance in Mandibular Overdentures Supported by Two Implants on Patient Satisfaction and Quality of Life

dc.authorid GECKILI, ONUR/0000-0002-7852-3915
dc.authorid Bilmenoglu, Caglar/0000-0002-2580-9899
dc.authorid Bilhan, Hakan/0000-0003-1787-3003
dc.authorid Cilingir, Altug/0000-0002-0694-5772
dc.authorscopusid 15135391400
dc.authorscopusid 14012620400
dc.authorscopusid 57197293393
dc.authorscopusid 56564008900
dc.authorscopusid 54880603900
dc.authorscopusid 56563983600
dc.authorscopusid 56563983600
dc.authorwosid GECKILI, ONUR/AAD-4973-2020
dc.authorwosid Bilmenoglu, Caglar/HGE-5706-2022
dc.authorwosid ozdiler, arda/U-1599-2018
dc.authorwosid Cilingir, Altug/N-2262-2018
dc.contributor.author Geckili, Onur
dc.contributor.author Cilingir, Altug
dc.contributor.author Erdogan, Ozge
dc.contributor.author Kesoglu, Aysun Coskun
dc.contributor.author Bilmenoglu, Caglar
dc.contributor.author Ozdiler, Arda
dc.contributor.author Bilhan, Hakan
dc.date.accessioned 2024-05-25T11:18:01Z
dc.date.available 2024-05-25T11:18:01Z
dc.date.issued 2015
dc.department Okan University en_US
dc.department-temp [Geckili, Onur; Erdogan, Ozge; Kesoglu, Aysun Coskun; Bilmenoglu, Caglar; Ozdiler, Arda] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Cilingir, Altug] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey; [Bilhan, Hakan] Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey en_US
dc.description GECKILI, ONUR/0000-0002-7852-3915; Bilmenoglu, Caglar/0000-0002-2580-9899; Bilhan, Hakan/0000-0003-1787-3003; Cilingir, Altug/0000-0002-0694-5772 en_US
dc.description.abstract This study evaluates the influence of interimplant distance (ID) on patient satisfaction and quality of life (QOL) of 55 patients who received mandibular overdentures supported by two implants. IDs were measured over the residual ridge crest and linearly on all of the patients' mandibular casts. The crestal detours of all patients were determined by subtracting these two values from each other. Higher IDs were associated with better QOL scores (P < .05), whereas higher crestal detour values were associated with better general comfort, chewing, ease of hygiene maintenance, esthetics, pain, and QOL scores (P < .05). en_US
dc.identifier.citationcount 9
dc.identifier.doi 10.11607/ijp.3994
dc.identifier.endpage 21 en_US
dc.identifier.issn 0893-2174
dc.identifier.issn 1942-4426
dc.identifier.issue 1 en_US
dc.identifier.pmid 25588167
dc.identifier.scopus 2-s2.0-84925282946
dc.identifier.scopusquality Q2
dc.identifier.startpage 19 en_US
dc.identifier.uri https://doi.org/10.11607/ijp.3994
dc.identifier.uri https://hdl.handle.net/20.500.14517/279
dc.identifier.volume 28 en_US
dc.identifier.wos WOS:000348489100004
dc.identifier.wosquality Q3
dc.language.iso en
dc.publisher Quintessence Publishing Co inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 13
dc.subject [No Keyword Available] en_US
dc.title The Influence of Interimplant Distance in Mandibular Overdentures Supported by Two Implants on Patient Satisfaction and Quality of Life en_US
dc.type Article en_US
dc.wos.citedbyCount 9

Files