The influence of MTAD and QMix on the accuracy of electronic apex locator in locating simulated perforations

dc.authorid yoldaş, hamdi oğuz/0000-0002-6887-1190
dc.authorid Dumani, Aysin/0000-0001-6519-9928
dc.authorid Yilmaz, Sehnaz/0000-0002-6742-5690
dc.authorscopusid 14522278600
dc.authorscopusid 57204595215
dc.authorscopusid 57538314800
dc.authorscopusid 54413469900
dc.authorscopusid 23480797700
dc.authorscopusid 6602558452
dc.authorwosid Unal, Ilker/E-5071-2018
dc.authorwosid yoldaş, hamdi oğuz/G-4026-2018
dc.authorwosid Dumani, Aysin/J-9943-2018
dc.authorwosid Yilmaz, Sehnaz/J-9960-2018
dc.contributor.author Dumani, A.
dc.contributor.author Ates, A. A.
dc.contributor.author Ucan, C. S.
dc.contributor.author Yilmaz, S.
dc.contributor.author Unal, I
dc.contributor.author Yoldas, O.
dc.date.accessioned 2024-05-25T11:25:27Z
dc.date.available 2024-05-25T11:25:27Z
dc.date.issued 2022
dc.department Okan University en_US
dc.department-temp [Dumani, A.; Ucan, C. S.; Yilmaz, S.; Yoldas, O.] Cukurova Univ, Fac Dent, Dept Endodont, Adana, Turkey; [Unal, I] Cukurova Univ, Fac Med, Dept Biostat, Adana, Turkey; [Ates, A. A.] Istanbul Okan Univ, Fac Dent, Dept Endodont, Istanbul, Turkey en_US
dc.description yoldaş, hamdi oğuz/0000-0002-6887-1190; Dumani, Aysin/0000-0001-6519-9928; Yilmaz, Sehnaz/0000-0002-6742-5690 en_US
dc.description.abstract Aims and Background: The aim of this study was to evaluate the accuracy of the electronic actual length in detecting artificial perforations of the root canal in the presence of saline solution (NaCl, (Eczacibasi, Istanbul, Turkey), chlorhexidine [CHX (Werax, Tunadent, Izmir, Turkey)], QMix (Dentsply Tulsa, Maillefer, Ballaigues, Switzerland), and MTAD (Dentsply, Tulsa Dental, Tulsa, OK, USA). Materials and Methods: The root canals of 25 single-rooted extracted human teeth were perforated artificially in the middle section of the root. The actual lengths up to the perforation site were measured and then, the teeth were embedded in an alginate mold. Electronic measurements of the perforations were obtained by an electronic apex locator according to the manufacturers' recommendations under dry conditions and in the presence of NaCl, CHX, MTAD, and QMix using a #20 K-file. Each canal was irrigated with distilled water and then dried with paper points between the measurements. Statistical analyses were performed using the Friedman test and Spearman Rank correlation coefficient to assess the correlations between the measurement methods. Results: Highest correlation between the actual length and the electronic measurement was observed under dry conditions and NaCl solution (r: 0.932, r: 0.940 respectively), and the least correlation was observed with MTAD solution (r: 0.697) using statistical analysis. Moreover, the accuracy of the electronic apex locator with different irrigation solutions was statistically different from each other (P = 0.001). Conclusion: The most accurate electronic measurements of artificial perforation were obtained under dry conditions or with NaCl. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.4103/njcp.njcp_1444_21
dc.identifier.endpage 285 en_US
dc.identifier.issn 1119-3077
dc.identifier.issue 3 en_US
dc.identifier.pmid 35295049
dc.identifier.scopus 2-s2.0-85126708173
dc.identifier.scopusquality Q2
dc.identifier.startpage 281 en_US
dc.identifier.uri https://doi.org/10.4103/njcp.njcp_1444_21
dc.identifier.uri https://hdl.handle.net/20.500.14517/904
dc.identifier.volume 25 en_US
dc.identifier.wos WOS:000884847100010
dc.identifier.wosquality Q4
dc.language.iso en
dc.publisher Wolters Kluwer Medknow Publications en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 1
dc.subject Apex locator en_US
dc.subject MTAD en_US
dc.subject QMix en_US
dc.subject root canal perforation en_US
dc.title The influence of MTAD and QMix on the accuracy of electronic apex locator in locating simulated perforations en_US
dc.type Article en_US
dc.wos.citedbyCount 0

Files