Influence of rotational speed and glide path on cyclic fatigue resistance of XP-endo shaper

dc.authorid Ounsi, Hani F./0000-0002-8610-3427
dc.authorscopusid 57204595215
dc.authorscopusid 56094357600
dc.authorscopusid 9267589900
dc.authorwosid Ounsi, Hani F./AAI-3955-2021
dc.authorwosid Ates, Ayfer Atav/ABC-2676-2022
dc.contributor.author Ates, A. Atav
dc.contributor.author Arican, B.
dc.contributor.author Ounsi, H. F.
dc.date.accessioned 2024-05-25T12:30:56Z
dc.date.available 2024-05-25T12:30:56Z
dc.date.issued 2020
dc.department Okan University en_US
dc.department-temp [Ates, A. Atav; Arican, B.] Istanbul Okan Univ, Fac Dent, Dept Endodont, Istanbul, Turkey; [Ounsi, H. F.] Lebanese Univ, Fac Dent Med, Dept Restorat Dent & Endodont, Beirut, Lebanon; [Ounsi, H. F.] Siena Univ, Fac Dent Med, Dept Endodont & Restorat Dent, Siena, Italy en_US
dc.description Ounsi, Hani F./0000-0002-8610-3427; en_US
dc.description.abstract Aim: The aim of this study was to evaluate the effect of the different rotational speeds and creating a glide path on cyclic fatigue resistance of XP-endo Shaper (R) (XPS) (FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) at intracanal temperature. Materials and Methods: Ninety-six XPS files were divided into 6 groups [directly used at 1000 rpm (G1) or 3000 rpm (G4), with glide path at 1000 rpm (G2) or 3000 rpm (G4), without glide path at 1000 rpm (G3) and 3000 rpm (G6)]. All the instruments were rotated in a stainless-steel artificial canal with a 75 degrees angle of curvature, 7.5 mm radius of curvature, and 1.3 mm inner diameter until the fracture occurred. The number of cycles to failure (NCF) and the length of the fractured (LF) segments were evaluated. Weibull analysis, one-way ANOVA, and Tukey multiple comparison tests were performed with the significance level set at 0.05. Results: NCF of 3000 rpm groups was statistically higher than that of 1000 rpm groups (P < 0.05). And time to fracture was found statistically higher in 1000 rpm as compared to 3000 rpm. The mean LF of the instruments was statistically insignificant (P > 0.05). There was no statistical difference within the groups subjected at 1000 rpm and 3000 rpm files used with or without a glide path (P > 0.05).Conclusion: Within the limitations of this in vitro study, it was determined that XPS can be used safely even at 3000 rpm speed with or without glide path. en_US
dc.identifier.citationcount 3
dc.identifier.doi 10.4103/njcp.njcp_26_20
dc.identifier.endpage 1448 en_US
dc.identifier.issn 1119-3077
dc.identifier.issue 10 en_US
dc.identifier.pmid 33047704
dc.identifier.scopus 2-s2.0-85092886596
dc.identifier.scopusquality Q2
dc.identifier.startpage 1443 en_US
dc.identifier.uri https://doi.org/10.4103/njcp.njcp_26_20
dc.identifier.uri https://hdl.handle.net/20.500.14517/2224
dc.identifier.volume 23 en_US
dc.identifier.wos WOS:000617098200017
dc.identifier.wosquality Q4
dc.language.iso en
dc.publisher Wolters Kluwer Medknow Publications en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 4
dc.subject 3D models en_US
dc.subject cyclic fatigue en_US
dc.subject glidepath en_US
dc.subject XP-endo shaper en_US
dc.title Influence of rotational speed and glide path on cyclic fatigue resistance of XP-endo shaper en_US
dc.type Article en_US
dc.wos.citedbyCount 6

Files