STRAIN CHARACTERISTICS OF MARBURG DOUBLE CROWN-RETAINED IMPLANT OVERDENTURES COMPARED WITH BAR AND BALL-RETAINED IMPLANT OVERDENTURES, WITH AND WITHOUT A RIGID MAJOR CONNECTOR

dc.authorid Akaltan, Funda Kadriye/0000-0001-6744-6312
dc.authorid KAZOKOGLU, SEHNAZ/0000-0001-5632-5814
dc.authorscopusid 56429618800
dc.authorscopusid 6506376078
dc.authorwosid KAZOKOĞLU, ŞEHNAZ/X-9518-2019
dc.authorwosid Akaltan, Funda Kadriye/AAV-9200-2021
dc.contributor.author Kazokoglu, F. Sehnaz
dc.contributor.author Akaltan, Funda
dc.date.accessioned 2024-05-25T11:18:00Z
dc.date.available 2024-05-25T11:18:00Z
dc.date.issued 2014
dc.department Okan University en_US
dc.department-temp [Kazokoglu, F. Sehnaz] Okan Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey; [Akaltan, Funda] Ankara Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey en_US
dc.description Akaltan, Funda Kadriye/0000-0001-6744-6312; KAZOKOGLU, SEHNAZ/0000-0001-5632-5814 en_US
dc.description.abstract Statement of problem. It is hard to identify the most favorable retainer type and the denture design when considering strain levels around implants and in edentulous ridges for implant overdentures (IOVD). Purpose. The purpose of this study was to evaluate the strain transmitted to the implants and edentulous ridges by Marburg double crown (MDC)-retained IOVD as opposed to bar and ball-retained IOVD and the efficiency of a rigid major connector in the maxilla. Material and methods. An in vitro maxillary model was prepared with 4 implants, with strain gauges placed distally to each implant and also in the anterior and posterior edentulous ridges. Five overdentures were fabricated for each MDC and each ball and bar attachment retainers. Vertical loads of 280 N were applied bilaterally on the first molar region. Then the palatal bars of each IOVD were disconnected, and loading procedures were repeated for the prostheses. Results. No significant difference was observed among the MDC and the bar and ball-retained IOVD, with and without a rigid bar according to the data taken from both the implants and edentulous ridges. However, when the strain values attained from each strain gauge separately were considered, a slight difference was observed around the implants of ball-retained overdentures and in the edentulous ridges of MDC-retained overdentures. Conclusions. Within the limitations of this in vitro study, MDC-retained maxillary overdentures with 4 parallel and symmetrically placed implants can be used safely without a rigid major connector as with bar and ball-retained IOVD with regard to the strains generated in the edentulous ridge and around implants. en_US
dc.description.sponsorship Astra Tech AB, Sweden [D-2007-63]; Department of Scientific Research Projects of Ankara University [20070802082] en_US
dc.description.sponsorship Supported by Astra Tech AB, Sweden, Reference D-2007-63; and Department of Scientific Research Projects of Ankara University, Project 20070802082. en_US
dc.identifier.citationcount 4
dc.identifier.doi 10.1016/j.prosdent.2014.05.013
dc.identifier.endpage 1424 en_US
dc.identifier.issn 0022-3913
dc.identifier.issn 1097-6841
dc.identifier.issue 6 en_US
dc.identifier.pmid 24969407
dc.identifier.scopus 2-s2.0-84912099914
dc.identifier.scopusquality Q1
dc.identifier.startpage 1416 en_US
dc.identifier.uri https://doi.org/10.1016/j.prosdent.2014.05.013
dc.identifier.uri https://hdl.handle.net/20.500.14517/273
dc.identifier.volume 112 en_US
dc.identifier.wos WOS:000345955900016
dc.identifier.wosquality Q1
dc.language.iso en
dc.publisher Mosby-elsevier en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 4
dc.subject [No Keyword Available] en_US
dc.title STRAIN CHARACTERISTICS OF MARBURG DOUBLE CROWN-RETAINED IMPLANT OVERDENTURES COMPARED WITH BAR AND BALL-RETAINED IMPLANT OVERDENTURES, WITH AND WITHOUT A RIGID MAJOR CONNECTOR en_US
dc.type Article en_US
dc.wos.citedbyCount 4

Files