Influence of different irrigation regimens on the dentinal tubule penetration of a bioceramic-based root canal sealer: a confocal analysis study

dc.authorid Ciftcioglu, Elif/0000-0002-2578-0168
dc.authorid Arican, Burcin/0000-0001-5757-0571
dc.authorscopusid 57204595215
dc.authorscopusid 56094357600
dc.authorscopusid 36196266900
dc.authorscopusid 57194700028
dc.authorwosid Ates, Ayfer Atav/ABC-2676-2022
dc.authorwosid Ciftcioglu, Elif/GQQ-9704-2022
dc.contributor.author Ates, Ayfer Atav
dc.contributor.author Arican, Burcin
dc.contributor.author Ciftcioglu, Elif
dc.contributor.author Kucukay, E. Sedat
dc.date.accessioned 2024-05-25T11:42:44Z
dc.date.available 2024-05-25T11:42:44Z
dc.date.issued 2021
dc.department Okan University en_US
dc.department-temp [Ates, Ayfer Atav; Arican, Burcin; Ciftcioglu, Elif; Kucukay, E. Sedat] Istanbul Okan Univ, Fac Dent, Dept Endodont, Istanbul, Turkey en_US
dc.description Ciftcioglu, Elif/0000-0002-2578-0168; Arican, Burcin/0000-0001-5757-0571 en_US
dc.description.abstract This study aims to assess the efficacy of various irrigation protocols on the dentinal tubule penetration of a bioceramic-based endodontic sealer. Sixty-four single-rooted extracted human mandibular incisors were used. After instrumentation, teeth were randomly divided into the following four groups (n = 16 each) according to the final irrigation technique: group 1, conventional endodontic needle (CEN); group 2, EndoActivator (EA); group 3, Er,Cr: YSGG laser; group 4, XP-endo Finisher (XPF). The root canals were finally irrigated with 17% EDTA and 5.25% NaOCl for 1 min (min) respectively. The teeth were then obturated with Endosequence BC Points and rhodamine B dye-labeled BC Sealer. After 2 weeks, 1-mm-thick transverse sections were cut 2 and 5 mm from the apex, and examined by confocal laser scanning microscopy at 5 x magnification. The total percentage of sealer penetration (TPSP), sealer penetration area (SPA), and maximum sealer penetration depth (MSPD) was measured. Data were analyzed by Kruskal-Wallis, Dunn's multiple comparison, and Wilcoxon tests, with significance set at P < 0.05. At 2 mm level, no significant differences were detected among the groups (P > 0.05). At the 5 mm level, the XPF group showed significantly higher values for both TPSP and SPA in comparison with the Er,Cr: YSGG laser and CEN groups (P < 0.05), but no significant difference was observed with the EA group. The choice of different final irrigation techniques can affect dentinal tubule penetration. en_US
dc.identifier.citationcount 6
dc.identifier.doi 10.1007/s10103-021-03356-4
dc.identifier.endpage 1777 en_US
dc.identifier.issn 0268-8921
dc.identifier.issn 1435-604X
dc.identifier.issue 8 en_US
dc.identifier.pmid 34148161
dc.identifier.scopus 2-s2.0-85108274011
dc.identifier.scopusquality Q1
dc.identifier.startpage 1771 en_US
dc.identifier.uri https://doi.org/10.1007/s10103-021-03356-4
dc.identifier.uri https://hdl.handle.net/20.500.14517/1632
dc.identifier.volume 36 en_US
dc.identifier.wos WOS:000663512800001
dc.identifier.wosquality Q2
dc.institutionauthor Çiftçioğlu E.
dc.language.iso en
dc.publisher Springer London Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 6
dc.subject Bioceramic sealer en_US
dc.subject Er,Cr:YSGG en_US
dc.subject EndoActivator en_US
dc.subject Sealer penetration en_US
dc.subject XP-endo Finisher en_US
dc.title Influence of different irrigation regimens on the dentinal tubule penetration of a bioceramic-based root canal sealer: a confocal analysis study en_US
dc.type Article en_US
dc.wos.citedbyCount 7

Files