The effects of diode and Er:YAG laser applications on the surface topography of titanium grade 4 and titanium zirconium discs with sand-blasted and acid-etched (SLA) surfaces

dc.authorid Avcu, Egemen/0000-0002-3244-1316
dc.authorid Kan, Bahadir/0000-0001-6980-2085
dc.authorid Meral, Salih Eren/0000-0002-5855-4570
dc.authorscopusid 57199090136
dc.authorscopusid 54910631000
dc.authorscopusid 57191866005
dc.authorscopusid 55812360800
dc.authorscopusid 56054985600
dc.authorscopusid 36183962200
dc.authorscopusid 36183962200
dc.authorwosid Avcu, Egemen/F-6772-2018
dc.authorwosid Kan, Bahadir/F-4799-2018
dc.contributor.author Ozturk, Anil
dc.contributor.author Tosun, Emre
dc.contributor.author Meral, Salih Eren
dc.contributor.author Bastan, Fatih Erdem
dc.contributor.author Ustel, Fatih
dc.contributor.author Kan, Bahadir
dc.contributor.author Avcu, Egemen
dc.date.accessioned 2024-05-25T11:28:18Z
dc.date.available 2024-05-25T11:28:18Z
dc.date.issued 2024
dc.department Okan University en_US
dc.department-temp [Ozturk, Anil] Oral & Maxillofacial Surg, Istanbul, Turkiye; [Tosun, Emre; Meral, Salih Eren] Hacettepe Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Ankara, Turkiye; [Bastan, Fatih Erdem; Ustel, Fatih] Sakarya Univ, Engn Fac, Dept Met & Mat Engn, Thermal Spray Res & Dev Lab, TR-54187 Sakarya, Turkiye; [Kan, Bahadir] Okan Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Istanbul, Turkiye; [Avcu, Egemen] Kocaeli Univ, Ford Otosan Ihsaniye Automot Vocat Sch, Machine & Met Technol, Surface Treatment Lab, TR-41680 Kocaeli, Turkiye en_US
dc.description Avcu, Egemen/0000-0002-3244-1316; Kan, Bahadir/0000-0001-6980-2085; Meral, Salih Eren/0000-0002-5855-4570 en_US
dc.description.abstract Background: Laser application for the treatment of peri-implantitis provides a variety of advantages; however, depending on the laser type and parameters, it may also have adverse effects on the implant surface qualities. This study's objective is to assess the effects of laser type and parameters on the surface properties of two different titanium-based implant materials: titanium Grade 4 (Ti-Grade 4) and titanium zirconium (Ti-Zr) discs with sand-blasted and acid-etched (SLA) surfaces under in vitro conditions. Material & method: Sand-blasted and acid-etched discs made of titanium grade 4 (Ti-Grade 4) and titanium zirconium (Ti-Zr) were treated using 808 nm AlGaAs (diode) and 2940 nm Er:YAG lasers with varying parameters (i.e., diode laser in continuous wave mode, Er:YAG in short pulse mode, and Er:YAG in variable square pulse mode with four different doses). Then, the surface morphology and topography of the treated discs were characterized using scanning electron microscopy and optical profilometry. Results: The 3D surface topographies of discs treated with a high power Er:YAG laser displayed irregular peaks and deep valleys, indicating surface deterioration. The average surface roughness values (Sa) of both discs varied with laser type and parameters (3.55-4.80 mm for Ti-Grade 4 versus 3.25-4.5 mm for Ti-Zr). With diode laser applications, the topography features of the discs were preserved despite a small number of irregular valleys and peaks. However, the surface morphologies of the discs were dramatically altered by erosion and local melting because of the Er:YAG laser treatment. Conclusion: Diode laser application appears to be the most reliable method for treating peri-implantitis, as diode laser-treated implants retained their overall surface quality despite a small number of irregular peaks and valleys. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.1016/j.jormas.2023.101680
dc.identifier.issn 2468-8509
dc.identifier.issn 2468-7855
dc.identifier.issue 3 en_US
dc.identifier.pmid 37951501
dc.identifier.scopus 2-s2.0-85179477821
dc.identifier.scopusquality Q3
dc.identifier.uri https://doi.org/10.1016/j.jormas.2023.101680
dc.identifier.uri https://hdl.handle.net/20.500.14517/1146
dc.identifier.volume 125 en_US
dc.identifier.wos WOS:001135455000001
dc.identifier.wosquality Q3
dc.institutionauthor Kan B.
dc.language.iso en
dc.publisher Elsevier en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 0
dc.subject Laser en_US
dc.subject Titanium-zirconium alloy en_US
dc.subject Periimplantitis en_US
dc.subject Surface topography en_US
dc.subject Surface morphology en_US
dc.subject Grade 4 titanium en_US
dc.title The effects of diode and Er:YAG laser applications on the surface topography of titanium grade 4 and titanium zirconium discs with sand-blasted and acid-etched (SLA) surfaces en_US
dc.type Article en_US
dc.wos.citedbyCount 1

Files