Radiographic Acetabulotrochanteric Distance Measurement as a Novel Method for Determining Leg Length Discrepancy in Patients with Hemiarthroplasty

dc.authorid Yuzuguldu, Ugur/0000-0002-3378-2497
dc.authorscopusid 57221823052
dc.authorscopusid 58289143700
dc.authorscopusid 59403606000
dc.authorscopusid 55890594200
dc.authorscopusid 8420801200
dc.authorwosid Yeşil, Murat/Aac-9612-2022
dc.authorwosid Yüzügüldü, Uğur/Izp-6792-2023
dc.authorwosid Yuzuguldu, Ugur/Izp-6792-2023
dc.contributor.author Yuzuguldu, Ugur
dc.contributor.author Yilmaz, Bilge Kagan
dc.contributor.author Butuner, Ibrahim Ethem
dc.contributor.author Yesil, Murat
dc.contributor.author Maralcan, Gokhan
dc.date.accessioned 2025-09-15T18:35:23Z
dc.date.available 2025-09-15T18:35:23Z
dc.date.issued 2025
dc.department Okan University en_US
dc.department-temp [Yuzuguldu, Ugur] Ataturk City Hosp, Dept Orthoped & Traumatol, Balikesir, Turkiye; [Yilmaz, Bilge Kagan; Yesil, Murat] Afyonkarahisar Hlth Sci Univ, Dept Orthoped & Traumatol, Afyonkarahisar, Turkiye; [Butuner, Ibrahim Ethem] Edremit State Hosp, Dept Orthoped & Traumatol, Balikesir, Turkiye; [Maralcan, Gokhan] Okan Univ Hosp, Dept Orthoped & Traumatol, Istanbul, Turkiye en_US
dc.description Yuzuguldu, Ugur/0000-0002-3378-2497 en_US
dc.description.abstract Objectives: This study aims to evaluate the interobserver reliability and interobserver reproducibility of radiographic acetabulotrochanteric distance (ATD) measurement and to investigate its accuracy by comparing it with conventional radiographic methods used in leg length discrepancy (LLD) measurement. Patients and methods: Between January 2017 and January 2022, a total of 97 patients (39 males, 58 females; mean age: 77.8 +/- 7.1 years; range, 61 to 91 years) who underwent pelvic radiographic evaluation and hemiarthroplasty (HA) due to femoral neck fracture were retrospectively analyzed. For ATD measurement, the distance between the line connecting the upper cartilage of the acetabulum (AC) and the extreme point of the greater trochanter (GT) was used. The AC-GT measurement on both sides was compared with bottom of the ischial tuberosities-lesser trochanter (BI-LT), center of the femoral head-BI (CH-BI), inferior acetabular teardrops-LT (IT-LT) measurements. The agreement between the methods was examined with the intraclass correlation coefficient (CCI). Results: According to the AC-GT & BI-LT, AC-GT & BI-CH methods, there were very strong (ICC: 0.75), moderate (ICC: 0.69) and acceptable (ICC: 0.33) agreements, respectively. Significant agreement was found between all measurements (p<0.001). A positive correlation was detected in the correlation analysis of all measurements (p<0.001). Intra-and interobserver agreement for ATD measurement (AC-GT) was excellent (ICC: >0.8). Conclusion: The ATD measurement correlates well with known measurement techniques on pelvic radiography and can be used as an alternative to this method. It has excellent intra-and interobserver agreements. This method can predict LLD after HA, but does not consider other length differences in the lower limbs. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.52312/jdrs.2025.2285
dc.identifier.endpage 682 en_US
dc.identifier.issn 2687-4792
dc.identifier.issue 3 en_US
dc.identifier.pmid 40784000
dc.identifier.scopus 2-s2.0-105013313841
dc.identifier.scopusquality Q3
dc.identifier.startpage 675 en_US
dc.identifier.uri https://doi.org/10.52312/jdrs.2025.2285
dc.identifier.uri https://hdl.handle.net/20.500.14517/8330
dc.identifier.volume 36 en_US
dc.identifier.wos WOS:001551684100021
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Turkish Joint Diseases Foundation en_US
dc.relation.ispartof Joint Diseases and Related Surgery en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Acetabulotrochanteric Distance en_US
dc.subject Hemiarthroplasty en_US
dc.subject Hip Joint en_US
dc.subject Leg Length Discrepancy en_US
dc.subject Pelvic Radiography en_US
dc.title Radiographic Acetabulotrochanteric Distance Measurement as a Novel Method for Determining Leg Length Discrepancy in Patients with Hemiarthroplasty en_US
dc.type Article en_US
dspace.entity.type Publication

Files